Coalescing Filters
We believe that filters always pay for themselves. Many gas lines have oil and water in mist or droplet form that, along with solid contaminants such as pipe scale, dirt, and rust, will damage or even destroy your downstream equipment. Use a FilterFab C-Series Coalescing Filter, and you will remove all forms of moisture and dry contamination, lengthening the life of your equipment and saving thousands of dollars in maintenance costs.
Description
C-Series Dry Filters have:
- 4 different closure styles. FilterFab has designed its lid closures to make filter element changeout as easy and as fast as possible. 2″ thru 6″ line sizes in 180 and 285 psi ratings use a quick-opening swing-bolt lid or blind flange, while larger and higher pressure filters incorporate a blind flange with lifting lug or a lifting davit. Optional threaded high-pressure closures are also available.
- 4 pressures (MAOP). Available in 180, 285, 740 and 1480 psi.
- 7 common line sizes. Choose from 2″ to 12″. Custom sizes to 24″ available.
- A wide range of flowrates. 18,000 to 17,000,000 scfh.
- Proprietary Coalescing Filter Cartridge. FilterFab’s C-Series coalescing filters use a proprietary reverse-flow, radially-finned, high surface area filter
- Cartridge unlike those used by any of our competitors. These cartridges are built with layers of borosilicate fiberglass sandwiched into layers
- Felted polyester media to remove 99.9% of all liquid droplets, fogs, and mists, plus all particulate matter down to 0.3-microns in size.
Call Meter, Valve & Control Sales Department for pricing and a representative in your area. Many model sizes are kept in stock for quick delivery.
Build a FilterFab C-Series Part Number
To choose the correct FilterFab model for your application, start by building a part number. You will need to know line size and pressure rating. See example below:
C-Series Filter Flowrate Information
Now check the model number you have determined above against the flowchart below to make sure that your choice will handle the flowrate of your application.
FLOWRATE in SCFH for C-Series Filters
|
||||||||||||
Model
Number |
Line Pressure (in psi) | |||||||||||
1/4 | 5 | 25 | 50 | 100 | 150 | 250 | 500 | 750 | 1000 | 1200 | 1400 | |
C2 | 17900 | 20000 | 38700 | 48000 | 65300 | 79800 | 175M | 240M | 295M | 400M | 465M | 546M |
C3 | 33000 | 42900 | 85000 | 98000 | 150M | 182M | 400M | 575M | 665M | 850M | 990M | 1.1MM |
C4 | 58000 | 85000 | 147M | 155M | 266M | 330M | 680M | 920M | 1.4MM | 1.8MM | 2.1MM | 2.3MM |
C6 | 168M | 190M | 350M | 390M | 637M | 770M | 1.4MM | 1.9MM | 2.2MM | 2.8MM | 3.5MM | 3.9MM |
C8 | 280M | 345M | 540M | 700M | 1.1MM | 1.4MM | 2.5MM | 3.5MM | 4.2MM | 5.6MM | 7.0MM | 7.7MM |
C10 | 385M | 636M | 770M | 1.3MM | 1.8MM | 2.1MM | 4.2MM | 5.3MM | 6.3MM | 8.4MM | 9.8MM | 12MM |
C12 | 600M | 840M | 1.5MM | 1.8MM | 2.8MM | 3.4MM | 6.2MM | 7.7MM | 9.8MM | 12MM | 15MM | 17MM |
These flowrates are based on 1-1/2 psi pressure drop up to 150 psi; 3 psi for higher line pressures.
Choose a Style
Now look at the styles below the flowrate chart to see the standard body and closure style of your filter.
Style 1
STYLE 1 – Quick-Opening Closure | ||||||||
PSI | Line
Size |
Model
Number |
Dimensions |
Filter
Element |
Downloads | |||
A | B | C | F | |||||
180
|
2″
|
C2-180F
|
40″
|
12″
|
18″
|
17″
|
422
|
|
180
|
3″
|
C3-180F
|
50″
|
15″
|
21″
|
18″
|
425
|
|
180
|
4″
|
C4-180F
|
60″
|
18″
|
29″
|
20″
|
415
|
|
180
|
6″
|
C6-180F
|
61″
|
20″
|
28″
|
24″
|
2035K907
|
|
285
|
2″
|
C2-285F
|
40″
|
12″
|
18″
|
17″
|
422
|
|
285
|
3″
|
C3-285F
|
50″
|
15″
|
21″
|
18″
|
425
|
|
285
|
4″
|
C4-285F
|
60″
|
18″
|
29″
|
20″
|
415
|
|
285
|
6″
|
C6-285F
|
61″
|
20″
|
28″
|
24″
|
2035K907
|
Style 2
STYLE 2 — Blind Flange with Lifting Lug | ||||||||
PSI | Line
Size |
Model
Number |
Dimensions |
Filter
Element |
Downloads | |||
A | B | C | F | |||||
285
|
8″
|
C8-285F
|
65″
|
18″
|
33″
|
28″
|
2054K907
|
|
740
|
2″
|
C2-740F
|
40″
|
12″
|
18″
|
17″
|
422
|
|
740
|
3″
|
C3-740F
|
50″
|
15″
|
21″
|
18″
|
425
|
|
740
|
4″
|
C4-740F
|
60″
|
18″
|
29″
|
20″
|
415
|
|
1480
|
2″
|
C2-1480F
|
41″
|
12″
|
18″
|
17″
|
422
|
|
1480
|
3″
|
C3-1480F
|
51″
|
15″
|
21″
|
18″
|
425
|
|
1480
|
4″
|
C4-1480F
|
61″
|
18″
|
29″
|
20″
|
415
|
Style 3
STYLE 3 — Blind Flange with Lifting Davit | ||||||||
PSI | Line
Size |
Model
Number |
Dimensions |
Filter
Element |
Downloads | |||
A | B | C | F | |||||
285
|
10″
|
C10-285F
|
86″
|
24″
|
46″
|
32″
|
(2)2070K907
|
|
285
|
12″
|
C12-285F
|
96″
|
24″
|
48″
|
40″
|
(2)2083K907
|
|
740
|
6″
|
C6-740F
|
62″
|
20″
|
28″
|
24″
|
2035K907
|
|
740
|
8″
|
C8-740F
|
72″
|
18″
|
33″
|
28″
|
2054K907
|
|
740
|
10″
|
C10-740F
|
87″
|
24″
|
46″
|
32″
|
(2)2070K907
|
|
740
|
12″
|
C12-740F
|
96″
|
24″
|
48″
|
40″
|
(2)2083K907
|
|
1480
|
6″
|
C6-1480F
|
62″
|
20″
|
28″
|
24″
|
2035K907
|
|
1480
|
8″
|
C8-1480F
|
72″
|
18″
|
33″
|
28″
|
2054K907
|
Style 4
STYLE 4 — Blind Flange with Hydraulic Davit | ||||||||
PSI | Line
Size |
Model
Number |
Dimensions |
Filter
Element |
Downloads | |||
A | B | C | F | |||||
1480
|
10″
|
C10-1480F
|
87″
|
24″
|
46″
|
32″
|
(2)2070K907
|
|
1480
|
12″
|
C12-1480F
|
97″
|
24″
|
48″
|
40″
|
(2)2083K907
|
We Love Special Designs!
Are there any special design changes we can make to the standard unit you have chosen to help you fit into a tight space, remove a particularly stubborn contaminant, resist a high temperature, or simply make your job easier? FilterFab started in business in 1983 by building special designs, so you can count on us to find a solution to your unique problem.
ASME Information
Housings are designed and built to ASME Boiler & Pressure Vessel Code, Section VIII, Division 1 specifications by Section IX certified welders but not U-Code stamped without an extra charge.